Principal Applications

  • 吸収
  • 疎水性有機物分離
  • 脱色 - 甘味料
  • 脱色 - ビールブロス
  • スルファメタジンの除去

Advantages

  • 高機械的強度
  • 標準合成吸着剤よりの大きな比表面積
  • イオン交換と疎水性吸着の2つの相互作用

Regulatory Approvals

  • IFANCA Halal認定
  • コーシャ認定
  • Compliant with FDA Regulation 21 CFR 173.25 for Food Treatment, Ion Exchangers
  • Europe Resolution ResAP (2004)3準拠
  • GMO/TSE/BSE フリー

Typical Packaging

  • 1 ft³ Sack
  • 25 L Sack
  • 5 ft³ Drum (Fiber)
  • 1 m³ Supersack
  • 42 ft³ Supersack

Typical Physical & Chemical Characteristics:

Polymer Structure ポリスチレン系ジビニルベンゼン架橋マクロポーラス型ポリマー
Appearance 球形ビード
Functional Group 3級アミン
Ionic Form 遊離塩基
総交換容量(最小) 0.2 eq/l (4.4 Kgr/ft³) (Cl-)
強塩基
水分含有率 44 - 50 % (Cl-)
粒径範囲 300 - 1200 µm
平均径 535 ± 85 µm
細孔容量(最小) 0.6 mL/g
均一係数 (最大) 1.4
可逆的膨張, FB → Cl- (最大) 5 %
比重 1.09
d50, ミクロポア 14 Å
許容pH、安定性 0 - 14
強塩基 (最大) 20 %
比表面積 (最小) 750 m²/g
見かけ密度 (概算) 685 - 720 g/L (42.8 - 45.0 lb/ft³)
温度制限 60 °C (140.0 °F) (遊離塩基)

油圧特性

Pressure Drop

The pressure drop across a bed of ion exchange resin depends on the particle size distribution, bed depth, and voids volume of the exchange material, as well as on the flow rate and viscosity of the influent solution. Factors affecting any of these parameters— such as the presence of particulate matter filtered out by the bed, abnormal compressibility of the resin, or the incomplete classification of the bed—will have an adverse effect, and result in an increased head loss. Depending on the quality of the influent water, the application and the design of the plant, service flow rates may vary from 10 to 40 BV/h.

Pressure Drop Across Resin Bed

Backwash

During up-flow backwash, the resin bed should be expanded in volume between 50 and 70% for at least 10 to 15 minutes. This operation will free particulate matter, clear the bed of bubbles and voids, and reclassify the resin particles ensuring minimum resistance to flow. When first putting into service, approximately 30 minutes of expansion is usually sufficient to properly classify the bed. It is important to note that bed expansion increases with flow rate and decreases with influent fluid temperature. Caution must be taken to avoid loss of resin through the top of the vessel by over expansion of the bed.

Backwash Expansion of Resin Bed