Affinity Resin Selector
Find the perfect Ecolab
resin for your monoclonal
antibody purification needs.
Find the perfect Ecolab
resin for your monoclonal
antibody purification needs.
As a global leader in resin technology, we develop and manufacture small beads that are used in the most regulated industries in the world to separate, remove or recover very specific elements and compounds.
Learn More
With 40 years of manufacturing expertise and 30 years of regulatory experience, we supply leading separation, purification and extraction technologies to support chromatography applications within the Pharma and Medical space.
Learn more
We are a world leader in resin-based separation, purification and extraction technology, that provides sustainable solutions for our environment, businesses and healthcare.
Learn More
Наши всегда готовые к работе группы технической поддержки и обслуживания делают дополнительный шаг, чтобы стать вашим самым надежным ресурсом. Мы здесь для вас.
This process involves a partial caustic regeneration and displacement, followed by a 150 °F, 15% NaCl treatment. The process is repeated until the maximum color eluted during the brine step drops to 1/5 of the highest color eluted during the first treatment. Details of the procedure described above are as follows:
The anion bed is backwashed, then regenerated with 2%-5% NaOH. The amount of caustic must be limited to approximately 1/3 of the normal dosage. The flow rate should be about 0.2 gpm per ft3. For ten minutes after this step is completed, a slow rinse or displacement should occur at the same 0.2 gpm per ft3. Then, 150 °F, 10-15% NaCl solution should be injected at 6.5-8 pounds per ft3. This should also be at a 0.2 gpm per ft3 flowrate. Finally, the “slow rinse or displace” step described earlier should be repeated. This time, however, note the time at which the eluted color is the highest. This observation should be about the most concentrated salt in the effluent. This process should be repeated (without backwashing) until the color eluted during the salting period is 1/5 of that observed during the first treatment.
It is important to realize the procedure is best completed on a regular or periodic schedule before the anion resin is appreciably fouled. If organic matter in the affluent is high, the above steps should be taken every 15 to 30 days. Note that if the underdrain is made of stainless steel, the HCl will attack it, and the resin will have to be moved to an alternate treatment vessel.
Purolite.com uses cookies to give you the best possible experience. By using Purolite.com, you consent to our use of cookies. If you do not wish to receive our cookies, adjust your browser settings. Read our Cookies Policy to learn more.