Polystyrenic Macroporous, Anion Resin, Free Base form, Ultrapure Water Grade
항상 준비된 기술 지원 및 서비스 팀은 가장 신뢰할 수 있는 리소스가 되기 위해 한 단계 더 나아갑니다. 우리는 당신을 위해 여기 있습니다.
| Polymer Structure | Macroporous polystyrene crosslinked with divinylbenzene | |
| Appearance | Spherical Beads | |
| Functional Group | N-methylglucamine | |
| Ionic Form | FB form | |
| Total Capacity (min.) | 0.6 eq/L (13.1 Kgr/ft³) (FB form) | |
| Moisture Retention | 61 - 67 % (Cl- form) | |
| Particle Size Range | 425 - 850 µm | |
| < 425 µm (max.) | 5 % | |
| TOC (max.) | < 5 ppb Δ TOC after 48 hours rinse at 30 BV/h (*) | |
| Uniformity Coefficient (max.) | 1.3 | |
| Specific Gravity | 1.1 | |
| Shipping Weight (approx.) | 670 - 730 g/L (41.9 - 45.6 lb/ft³) | |
| Temperature Limit | 60 °C (140.0 °F) | |
| Footnote | * Influent rinse water quality : > 17.5 MΩ cm; < 2 ppb TOC | |
The pressure drop across a bed of ion exchange resin depends on the particle size distribution, bed depth, and voids volume of the exchange material, as well as on the flow rate and viscosity of the influent solution. Factors affecting any of these parameters— such as the presence of particulate matter filtered out by the bed, abnormal compressibility of the resin, or the incomplete classification of the bed—will have an adverse effect, and result in an increased head loss. Depending on the quality of the influent water, the application and the design of the plant, service flow rates may vary from 10 to 40 BV/h.
Purolite.com uses cookies to give you the best possible experience. By using Purolite.com, you consent to our use of cookies. If you do not wish to receive our cookies, adjust your browser settings. Read our Cookies Policy to learn more.